Initial test force |
98.07N (10kgf) |
Total test force |
Rockwell: 588N(60kgf) , 980N(100kgf) , 1471N(150kgf)
Brinell: 306.5N(31.25kgf) , 612.9N(62.5kgf) , 1839N(187.5kgf)
Vickers: 294.2N(30kgf), 980.7N(100kgf) |
Scale range |
Rockwell: HRA, HRB, HRC
Brinell:HBW2.5/31.25, HBW2.5/62.5, HBW5/62.5, HBW2.5/187.5
Vickers: HV30, HV100 |
Measuring range |
Rockwell: 20-95HRA, 10-100HRBW, 20-70HRC
Brinell: 5-650HBW
Vickers: 5-3000HV |
Lens magnification |
100X, 50X, 25X |
Appearance size and power |
Distance between indenter center and wall: 160mm;
Maximum allowable height of specimen: Rockwell 200mm, Brinell Vickers 180mm
Dimensions: 550*290*730mm;
Power: AC220V / 50Hz;